Explosion-proof signalling luminaire AWL
Explosion-proof barrier lights of AWL series are designed for installation on high-rise buildings (towers) and are intended for light marking or light barrier of high-rise and extended objects, which may impair safety conditions for moving objects (aeroplanes, helicopters, hang-gliders, etc.) at night and at dusk, as well as during the day in poor visibility conditions.
The luminaires can be operated in either constant burning or flashing mode.
These luminaires are installed indoors, outdoors in potentially hazardous areas in the presence of explosive and flammable gases and dust.
|
CODE |
LAMP TYPE |
TEMPERATURE CLASS |
SPRING, x/min |
CONNECTING |
DRAWING |
|
|
GAS |
DUST |
|||||
|
EVAC201 – F |
100W TUNING LAMP |
T4 |
Т 135° С |
– |
1 х 3/4“ |
A |
|
EVAC200-F |
100 W TUNING LAMP |
T4 |
Т 135 °С |
– |
2 х 3/4“ |
A-1 |
|
EVAC201-XF |
2J XENON FLASH LAMP |
T6 |
Т 85°С |
65+/-10 |
1 х 3/4“ |
C |
|
EVAC200-XF |
2J XENON FLASH LAMP |
T6 |
Т 85°С |
65+/-10 |
2 х 3/4“ |
C-1 |
|
EVAC201-F2R |
2 x 100 W TUNNEL LAMP |
T4 |
Т 135° С |
– |
2 х 3/4“ |
B |
|
EVAC201-XF2R |
2 x 2J КСЕНОНОВАЯ ЛАМПА-ВСПЫШКА |
T6 |
Т 85°С |
65+/-10 |
2 х 3/4“ |
D |
|
EVAC301-25R |
40W TUNING LAMP |
T4 |
Т 135° С |
– |
1 х 3/4“ |
C |
|
EVAC300-25R |
40W TUNING LAMP |
T4 |
Т 135° С |
– |
2 х 3/4“ |
C-1 |
Technical specifications
|
Execution |
II 2 G Ex d IIC T6/T4 Gb II 2 D Ex tb IIIC T85°C/T135°C Db |
|
Compliance |
EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-3 |
|
Protection level |
IP66 |
|
Body |
copper-free marine aluminium |
|
diffuser |
high temperature resistant impact resistant borosilicate glass |
|
Colour |
powder-coated, epoxy, grey RAL-9006 |
|
Bolts |
stainless steel |
|
Gasket |
silicone rubber |
|
Cartridge |
Е27 |
|
Cable connection |
3/4“NPT |
|
Terminals |
for cable connection up to 4mm² |
|
Wiring |
cables with silicone insulation resistant to high temperatures |
|
Average intensity |
signal group with flashing light, intensity 1450 / 2000 cd ( above 45m ) |
|
Low intensity |
signal group with constant light, intensity 30 cd (up to 45m) |
|
Realisation |
single fire – double fire ( 1 main + 1 reserve ) in accordance with ICAO recommendations |
Accessories on request:
- Stainless steel protective grille
- Fastening of the signalling group and control panel according to customer specifications
- External epoxy coating with colour on request
- Threaded connection other than standard connection
- Xenon flash lamp 6j
- Voltage different from the standard voltage