{"id":3627,"date":"2018-05-04T00:46:37","date_gmt":"2018-05-03T21:46:37","guid":{"rendered":"http:\/\/extechno.com.ua\/explosion-proof-safety-switches-10-a\/"},"modified":"2024-07-05T12:35:32","modified_gmt":"2024-07-05T09:35:32","slug":"explosion-proof-safety-switches-10-a","status":"publish","type":"post","link":"https:\/\/extechno.com.ua\/en\/explosion-proof-safety-switches-10-a\/","title":{"rendered":"Explosion-proof safety switches 10 A"},"content":{"rendered":"<p><strong>Technical specifications<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"692\">\n<p><strong>Explosion-proof safety switches 10 A<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>Mark<\/p>\n<\/td>\n<td width=\"462\">\n<p>II 2 G Ex ed IIC T6<\/p>\n<p>II 2 D Ex tD A21 IP66 T80 \u00b0C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>EU certificate<\/p>\n<\/td>\n<td width=\"462\">\n<p>PTB 00 ATEX 1074<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>Certificate of Conformity<\/p>\n<\/td>\n<td width=\"462\">\n<p>IECEx BKI 07.0014<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>Mark<\/p>\n<\/td>\n<td width=\"462\">\n<p>Ex ed IIC T6<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>Permissible ambient temperature<\/p>\n<\/td>\n<td width=\"462\">\n<p>-20\u00b0C to +40\u00b0C <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>Nominal voltage<\/p>\n<\/td>\n<td width=\"462\">\n<p>max. 500 V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>Rated current<\/p>\n<\/td>\n<td width=\"462\">\n<p>max. 10 A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>Frequency<\/p>\n<\/td>\n<td width=\"462\">\n<p>50\/60 Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>Rated switching on\/off capacity AC-3<\/p>\n<\/td>\n<td width=\"462\">\n<p>230 V Ue \/ Ie 10 A<br \/>\n400 V Ue \/ Ie 10 A<br \/>\n500 V Ue \/ Ie 10 A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>Input fuse<\/p>\n<\/td>\n<td width=\"462\">\n<p>400 V AC: 20 A gL<br \/>\n500 V AC: 16 A gL<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>Cable coupling\/hole in the housing<\/p>\n<\/td>\n<td width=\"462\">\n<p>M20 (d = 5 &#8230;13 mm) see ordering data<br \/>\nM20 (d = 8&#8230;17 mm) see ordering data<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>Protection class<\/p>\n<\/td>\n<td width=\"462\">\n<p>I<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>Degree of protection according to EN 60529<\/p>\n<\/td>\n<td width=\"462\">\n<p>IP66<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>Enclosure material<\/p>\n<\/td>\n<td width=\"462\">\n<p>impact-resistant polyamide<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>Case colour<\/p>\n<\/td>\n<td width=\"462\">\n<p>black<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>Auxiliary contact<\/p>\n<\/td>\n<td width=\"462\">\n<p>1 x NO switching on &#8211; lagging; switching off &#8211; advance<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">\n<p>Locking device<\/p>\n<\/td>\n<td width=\"462\">\n<p>can be locked in the OFF position with 3 commercially available padlocks<br \/>\nlocks (\u00f8 max. 6 mm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ebebeb;\" width=\"230\">\n<p>&nbsp;<\/p>\n<\/td>\n<td style=\"background-color: #ebebeb;\" width=\"462\">\n<p>&nbsp;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"692\">\n<p><b>Ordering data<\/b><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">3-pin with cable glands 2 x M25 \/ 1 x M 20<\/td>\n<td width=\"462\">GHG 261 0005 R0009<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">3-pin with cable glands 2 x M20<\/td>\n<td width=\"462\">GHG 261 0005 R0005<\/td>\n<\/tr>\n<tr>\n<td width=\"230\">3-pin emergency switch with cable glands 2 x M25 \/ 1 x M 20<\/td>\n<td width=\"462\">GHG 261 0005 R0010<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Technical specifications Explosion-proof safety switches 10 A Mark II 2 G Ex ed IIC T6 II 2 D Ex tD A21 IP66 T80 \u00b0C EU certificate PTB 00 ATEX 1074 Certificate of Conformity IECEx BKI 07.0014 Mark Ex ed IIC T6 Permissible ambient temperature -20\u00b0C to +40\u00b0C Nominal voltage max. 500 V Rated current max. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2652,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[181],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/posts\/3627"}],"collection":[{"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/comments?post=3627"}],"version-history":[{"count":1,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/posts\/3627\/revisions"}],"predecessor-version":[{"id":3628,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/posts\/3627\/revisions\/3628"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/media\/2652"}],"wp:attachment":[{"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/media?parent=3627"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/categories?post=3627"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/tags?post=3627"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}