{"id":3541,"date":"2018-05-19T12:14:22","date_gmt":"2018-05-19T09:14:22","guid":{"rendered":"http:\/\/extechno.com.ua\/double-core-heating-cable-for-floor-heating-ctav-10\/"},"modified":"2025-03-24T14:40:21","modified_gmt":"2025-03-24T11:40:21","slug":"double-core-heating-cable-for-floor-heating-easycable-ec","status":"publish","type":"post","link":"https:\/\/extechno.com.ua\/en\/double-core-heating-cable-for-floor-heating-easycable-ec\/","title":{"rendered":"Two-wire heating cable for a warm floor Easytherm 18W\/m"},"content":{"rendered":"<table style=\"height: 866px;\">\n<tbody>\n<tr style=\"height: 56px;\">\n<td style=\"height: 56px; width: 627px;\" colspan=\"2\">\n<p><strong>Technical specifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"height: 56px; width: 310px;\">\n<p>Linear power<\/p>\n<\/td>\n<td style=\"height: 56px; width: 311px;\">\n<p>18 W\/m (at 230 V)<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"height: 56px; width: 310px;\">\n<p>Minimum bending radius<\/p>\n<\/td>\n<td style=\"height: 56px; width: 311px;\">\n<p>at least eight cable diameters<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"height: 56px; width: 310px;\">\n<p>Permissible element resistance error<\/p>\n<\/td>\n<td style=\"height: 56px; width: 311px;\">\n<p>-5\/+10%<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"height: 56px; width: 310px;\">\n<p>Nominal voltage<\/p>\n<\/td>\n<td style=\"height: 56px; width: 311px;\">\n<p>230 V (+\/- 5%)<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"height: 56px; width: 310px;\">\n<p>Maximum operating temperature<\/p>\n<\/td>\n<td style=\"height: 56px; width: 311px;\">\n<p>+80\u00b0C<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"height: 56px; width: 627px;\" colspan=\"2\">\n<p><strong>Cable construction<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"height: 56px; width: 310px;\">\n<p>Heating part conductor<\/p>\n<\/td>\n<td style=\"height: 56px; width: 311px;\">\n<p>Double-core resistive conductor<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"height: 56px; width: 310px;\">\n<p>Power cable conductor<\/p>\n<\/td>\n<td style=\"height: 56px; width: 311px;\">\n<p>Length 2m.<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"height: 56px; width: 310px;\">\n<p>Insulation of the heating element<\/p>\n<\/td>\n<td style=\"height: 56px; width: 311px;\">\n<p>\u0424\u0442\u043e\u0440\u043e\u043f\u043e\u043b\u0456\u043c\u0435\u0440 (FLUON ETFE)<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"height: 56px; width: 310px;\">\n<p><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Protective screen<\/span><\/span><\/span><\/p>\n<\/td>\n<td style=\"height: 56px; width: 311px;\"><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">aluminum foil, aluminum wire Protective screen<\/span><\/span><\/span><\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"height: 56px; width: 310px;\">\n<p>Outer shell<\/p>\n<\/td>\n<td style=\"height: 56px; width: 311px;\">\n<p>Polyvinyl chloride (PVC)<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 80px;\">\n<td style=\"height: 80px; width: 310px;\">\n<p>Connection type of heating cable and power supply cable<\/p>\n<\/td>\n<td style=\"height: 80px; width: 311px;\">\n<p>coupling<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"height: 56px; width: 310px;\">\n<p>Outer diameter<\/p>\n<\/td>\n<td style=\"height: 56px; width: 311px;\">\n<p>4mm.<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 58px;\">\n<td style=\"height: 58px; width: 310px;\"><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Guarantee<\/span><\/span><\/span><\/td>\n<td style=\"height: 58px; width: 311px;\">\n<p><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">20 years<\/span><\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Technical specifications Linear power 18 W\/m (at 230 V) Minimum bending radius at least eight cable diameters Permissible element resistance error -5\/+10% Nominal voltage 230 V (+\/- 5%) Maximum operating temperature +80\u00b0C Cable construction Heating part conductor Double-core resistive conductor Power cable conductor Length 2m. Insulation of the heating element \u0424\u0442\u043e\u0440\u043e\u043f\u043e\u043b\u0456\u043c\u0435\u0440 (FLUON ETFE) Protective screen [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4296,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[256],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/posts\/3541"}],"collection":[{"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/comments?post=3541"}],"version-history":[{"count":7,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/posts\/3541\/revisions"}],"predecessor-version":[{"id":4315,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/posts\/3541\/revisions\/4315"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/media\/4296"}],"wp:attachment":[{"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/media?parent=3541"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/categories?post=3541"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/tags?post=3541"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}