{"id":3440,"date":"2019-05-07T15:50:14","date_gmt":"2019-05-07T12:50:14","guid":{"rendered":"http:\/\/extechno.com.ua\/explosion-proof-air-conditioner-fks-clm-for-zone-1\/"},"modified":"2024-06-27T13:12:21","modified_gmt":"2024-06-27T10:12:21","slug":"explosion-proof-air-conditioner-fks-clm-for-zone-1","status":"publish","type":"post","link":"https:\/\/extechno.com.ua\/en\/explosion-proof-air-conditioner-fks-clm-for-zone-1\/","title":{"rendered":"Explosion-proof air conditioner FKS-CLM for zone 1"},"content":{"rendered":"<p><strong>Explosion-proof air conditioner FKS-CLM technical data:<\/strong><\/p>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"1\">\n<tbody>\n<tr>\n<td style=\"width: 50%;\">Explosion protection marking<\/td>\n<td style=\"width: 50%;\">II 2G Ex px mb e IIC T3<br \/>\nII 2G EEx d\/e [ia] IIC T4<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">Ambient temperature (when cooling)<\/td>\n<td style=\"width: 50%;\">-20 \u00b0C \u0434\u043e +55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">Ambient temperature (without cooling)<\/td>\n<td style=\"width: 50%;\">-35 \u00b0C to +55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">Dust and moisture protection level<\/td>\n<td style=\"width: 50%;\">IP 56<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">Nominal voltage<\/td>\n<td style=\"width: 50%;\">400 V\/50 Hz AC; AC 440 V\/60 Hz<br \/>\n400 V\/50 Hz AC; AC 460 V\/60 Hz &#8211; for 4 kW version<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">Inrush current<\/td>\n<td style=\"width: 50%;\">\n<p>8 A<\/p>\n<p>16 A &#8211; for 4 kW version<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">Rated current<\/td>\n<td style=\"width: 50%;\">\n<p>4.5 A<\/p>\n<p>8.2 A &#8211; for 4 kW version<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">Backup fuse<\/td>\n<td style=\"width: 50%;\">\n<p>10 A<\/p>\n<p>16 A &#8211; for 4 kW version<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">Effective cooling capacity<\/td>\n<td style=\"width: 50%;\">\n<p>Q0 = approx. 2000 W (35 \u00b0C\/35 \u00b0C)<br \/>\nQ0 = approx. 4000 W (35 \u00b0C\/35 \u00b0C) &#8211; for 4 kW version<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">Heating capacity<\/td>\n<td style=\"width: 50%;\">\n<p>800 W<\/p>\n<p>1500 W &#8211; for 4 kW version<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">Refrigerant<\/td>\n<td style=\"width: 50%;\">R134a volume approx. 1200 g<br \/>\nR134a volume of approx. 2400 g &#8211; for 4 kW version<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">Noise level<\/td>\n<td style=\"width: 50%;\">75 dB (A)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">Condensate drainage<\/td>\n<td style=\"width: 50%;\">automatic (maintenance-free)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">Enclosure material<\/td>\n<td style=\"width: 50%;\">electrically conductive glass fibre reinforced polyester<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">Dimensions (height x width x depth)<\/td>\n<td style=\"width: 50%;\">1646 mm x 466 mm x 380 mm<br \/>\n1845 mm x 600 mm x 451 mm &#8211; for 4 kW version<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Ordering code:<\/p>\n<p><strong>FKS 2 &#8211; CLM \/*\/*\/*<\/strong>,<\/p>\n<p> <strong> FKS 4 &#8211; CLM \/*\/*\/*<\/strong>,<\/p>\n<p>where *- is special additional functions and features of the explosion-proof air-conditioner (please contact Ex Technologies Ltd. to specify them).<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Explosion-proof air conditioner FKS-CLM technical data: Explosion protection marking II 2G Ex px mb e IIC T3 II 2G EEx d\/e [ia] IIC T4 Ambient temperature (when cooling) -20 \u00b0C \u0434\u043e +55 \u00b0C Ambient temperature (without cooling) -35 \u00b0C to +55 \u00b0C Dust and moisture protection level IP 56 Nominal voltage 400 V\/50 Hz AC; [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2842,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[198],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/posts\/3440"}],"collection":[{"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/comments?post=3440"}],"version-history":[{"count":1,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/posts\/3440\/revisions"}],"predecessor-version":[{"id":3441,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/posts\/3440\/revisions\/3441"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/media\/2842"}],"wp:attachment":[{"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/media?parent=3440"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/categories?post=3440"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/extechno.com.ua\/en\/wp-json\/wp\/v2\/tags?post=3440"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}